Validation of the YuWell YE990 automatic oscillometric blood pressure monitor in mid-to-late pregnancy according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Common Criteria (AAMI/ESH/ISO 81060-2:2018/Amd.1:2020
Author: Du, Xue; Wang, Xiaoyue; Li, Xuan; Li, Tengteng; Lv, Wenjie; Yin, Zongzhi
Journal: BLOOD PRESSURE MONITORING. 2026; Vol. 31, Issue 2, pp. 95-100. DOI: 10.1097/MBP.0000000000000787
-
Validation of the CONTEC08C oscillometric blood pressure monitor in adults according to the International Organization for Standardization 81060-2:2018 standar
Author: Chen, Mengjia; Wang, Wenjie; Wang, Lu; Bian, Jin; Ma, Wenjun; Bai, Jingjing; Lou, Ying; Cai, Jun
Journal: BLOOD PRESSURE MONITORING. 2026; Vol. 31, Issue 2, pp. 86-89. DOI: 10.1097/MBP.0000000000000781
-
Combination of treatment intensity score and interankle diastolic blood pressure is associated with cardiovascular prognosis among adults with controlled hypertension who have pre-existing cardiovascular diseas
Author: Zhang, Zhe; Fan, Zeyuan; Han, Limin
Journal: BLOOD PRESSURE MONITORING. 2026; Vol. 31, Issue 1, pp. 21-28. DOI: 10.1097/MBP.0000000000000775
-
Validation of the DBP-6279B arm-type fully automatic digital blood pressure monitor in pregnancy according to the ISO 81060-2:2018/AMD 1:2020 protoco
Author: Yang, Rong; Li, Fen
Journal: BLOOD PRESSURE MONITORING. 2026; Vol. 31, Issue 1, pp. 49-52. DOI: 10.1097/MBP.0000000000000779
-
Effect of nifedipine combined with magnesium sulfate on gestational hypertension and its impact on blood lipid
Author: Cheng, Hong; Xing, Shaoning; Fu, Aizhen; Li, Hengjing
Journal: BLOOD PRESSURE MONITORING. 2026; Vol. 31, Issue 1, pp. 29-34. DOI: 10.1097/MBP.0000000000000780
-
Validation of the YuWell YE990 medical automatic electronic blood pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018/Amd.1:2020
Author: Xu, Dongju; Tang, Haiqin; Wang, Cuidi; Cheng, Hui; Wu, Wenhui; Lu, Qi; Liu, Hejun
Journal: BLOOD PRESSURE MONITORING. 2025; Vol. 30, Issue 4, pp. -. DOI: 10.1097/MBP.0000000000000755
-
Influence of cuff size on the accuracy of supine blood pressure measuremen
Author: Meiyan, Song; Zheng, Junwei; Ying, Wu; Wen, Chen; Kaizu, Xu; Lin, Liming
Journal: BLOOD PRESSURE MONITORING. 2025; Vol. 30, Issue 4, pp. 169-174. DOI: 10.1097/MBP.0000000000000752
-
Association between inter-arm blood pressure difference and prevalence of renal artery stenosis in patients with ischemic strok
Author: Li, Haiwen; Liu, Li; Tang, Xianbi; Jing, Kaiquan; Pan, Chuzheng
Journal: BLOOD PRESSURE MONITORING. 2025; Vol. 30, Issue 4, pp. 175-180. DOI: 10.1097/MBP.0000000000000753